LinkQnet 5KVA 5000W 48VDC XRT ONLINE UPS/INVERTER WITH 60A AC CHARGER

FEATURES: 

  • True online double-conversion
  • Zero transfer time
  • Pure Sine-wave output
  • Output Power Factor 1.0
  • Configurable charging current via LCD setting
  • Compatible with Generator
  • Cold Start capability
  • Overload and short circuit protection
  • Emergency Power Off (EPO) Function
  • Very powerful AC charger at 60A
  • Optional parallel operation up to 9 units for Single Phase and Three Phase application
  • Common 48Vdc battery pack for the parallel system
  • Full Bridge inverter design to support half-wave load and unbalanced load
  • USB, RS-232 and optional UPS SNMP LAN Card Slot
  • Anderson DC Connector for hot plug battery replacement

7 in stock

SKU: UPS-INV-5KVA-X Categories: , , , , Tags: , , ,

Versatile 5KVA 48VDC XT True Online UPS/Inverter for data centre and residential use

Features: 

  • True online double-conversion
  • Zero transfer time
  • Pure Sine-wave output
  • Output Power Factor 1.0
  • Configurable charging current via LCD setting
  • Compatible with Generator
  • Cold Start capability
  • Overload and short circuit protection
  • Emergency Power Off (EPO) Function
  • Very powerful AC charger at 60A
  • Optional parallel operation up to 9 units for Single Phase and Three Phase application
  • Common 48Vdc battery pack for the parallel system
  • Full Bridge inverter design to support half-wave load and unbalanced load
  • USB, RS-232 and optional UPS SNMP LAN Card Slot
  • Anderson DC Connector for hot plug battery replacement
SPECIFICTATIONS
Capacity 5000 VA / 5000 W
INPUT
Voltage:
Voltage Range:

Frequency Range:

Power Factor:
THDi:
220/230/240 VAC
110-280 VAC @ 50% load
176-280 VAC @ 100% load
46~54 Hz or 56~64 Hz
≧ 0.98 @ Nominal Voltage (100% Load)
≦ 8%
OUTPUT
Output Voltage:
AC Voltage Regulation (Batt. Mode):
Frequency Range (Synchronized Range):
Frequency Range (Batt. Mode):
Current Crest Ratio:
Harmonic Distortion:

Transfer Time - AC to Inverter Mode:
Transfer Time - Inverter to Bypass:
Waveform:
Output Voltage 220/230/240 VAC
± 1%
46~54 Hz or 56~64 Hz
50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
3:1
≦ 3% THD (Linear Load)
≦ 5 % THD (Non-linear Load)
Zero
4 ms (Typical)
Pure Sinewave
EFFICIENCY
Line Mode:
ECO Mode:
Battery Mode:
93.0%
99.5%
91.0%
BATTERIES
Battery Voltage:
Floating Charge Voltage:
Overcharge Protection:
Charging Current (max.):
48 VDC
54.6 VDC
60 VDC
60 A
INDICATORS
LCD:
Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicator Via LCD
Dimensions 465 x 190 x 318 mm
15.5 kg
ENVIRONMENT
Humidity:
Operating Temperature:
Storage Temperature:
0 to 95% Relative Humidity(Non-condensing)
0°C to 50°C
-15°C to 60°C
0