2KVA 1600W ONLINE TOWER UPS WITH 4X12V9AH BATTERIES
FEATURES:
- True double-conversion
- Microprocessor control optimizes reliability
- Input power factor correction
- Output power factor 0.8
- Wide input voltage (110 V – 300 V)
- Converter mode available
- ECO mode for energy saving (Only available for 1-3KVA)
- Generator compatible
- Adjustable battery number only available for 6K and up models
- Smart SNMP works well with either USB or RS-232 together
- Emergency power off function (EPO) only available for 6K/10K models
- Optional isolation transformer available
Out of stock
2kVa 1600W Online Tower UPS with 4X12V9Ah Batteries
Features:
- True double-conversion
- Microprocessor control optimizes reliability
- Input power factor correction
- Output power factor 0.8
- Wide input voltage (110 V – 300 V)
- Converter mode available
- ECO mode for energy saving (Only available for 1-3KVA)
- Generator compatible
- Adjustable battery number only available for 6K and up models
- Smart SNMP works well with either USB or RS-232 together
- Emergency power off function (EPO) only available for 6K/10K models
- Optional isolation transformer available.
SPECIFICTATIONS | |
Phase | Single phase with ground |
Capacity | 2000 VA / 1600 W |
INPUT Nominal Voltage: Input Voltage Range: Frequency Range: Power Factor: |
100/110/115/120/127VAC or 200/208/220/230/240VAC 55-150 VAC or 110-300 VAC (Based on load at 50%) 85-140VAC or 160-280VAC (Based on load at 100%) 40 Hz ~ 70 Hz ≧0.99 @ Nominall Voltage (100% load) |
OUTPUT Output Voltage: Voltage Regulation: Frequency Range (Synchronized Range): Frequency Range (Batt. Mode): Current Crest Ratio: Harmonic Distortion: AC Mode to Battery Mode Transfer Time: Inverter to Bypass Transfer Time: Waveform (Batt. Mode): |
100/110/115/120/127VAC or 200/208/220/230/240VAC ± 1 % 47~ 53 Hz or 57 ~ 63 Hz 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz 3:1 ≦ 3 % THD (Linear Load) ≦ 6 % THD (Non-linear Load) Zero 4 ms (Typical) Pure Sinewave |
EFFICIENCY AC Mode: Battery Mode: |
88% 87% |
BATTERY Battery Type: Numbers: Typical Recharge Time: Charging Current (max.): Charging Voltage: |
12 V / 9 Ah 4 4 hours recover to 90% capacity 1 A 54.7 VDC ±1% |
INDICATORS LCD: |
Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators |
ALARM Battery Mode: Low Battery: Overload: Fault: |
Sounding every 4 seconds Sounding every second Sounding twice every second Continuously sounding |
Dimensions | 397 x 145 x 220 mm 17 kg |
ENVIRONMENT Humidity: Noise Level: |
20-90 % RH @ 0- 40°C (Non-condensing) Less than 50dB @ 1 Meter |
MANAGEMENT Smart RS-232 / USB: Optional SNMP: |
Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux and MAC Power management from SNMP manager and web browser |